Product
LRS-75-12V/24V/48V
- Product details
-
■Features
‧Universal AC input / Full range
‧Withstand 300VAC surge input for 5 second
‧No load power consumption<0.3W
‧Miniature size and 1U low profile
‧High operating temperature up to 70℃
‧Protections: Short circuit / Overload / Over voltage
‧Cooling by free air convection
‧Compliance to IEC/BS EN/EN 60335-1(PD3) and IEC/BS EN/EN61558-1, -2-16 for household appliances
‧Operating altitude up to 5000 meters (Note.7)
‧Withstand 5G vibration test
‧High efficiency, long life and high reliability
‧LED indicator for power on
‧Over voltage category Ⅲ
‧100% full load burn-in test
‧3 years warranty
■ Applications
‧Industrial automation machinery
‧Industrial control system
·Mechanical and electrical equipment
·Electronic instruments, equipments or apparatus
·Household appliances
■Description
LRS-75 series is a 75W single-output enclosed type power supply with 30mm of low profile design. Adopting the full range 85~264VAC input, the entire series provides an output voltage line of 5V, 12V, 15V, 24V, 36V and 48V.
In addition to the high efficiency up to 91.5%, the design of metallic mesh case enhances the heat dissipation of LRS-75 that the whole series operates from -30℃ through 70℃ under air convection without a fan. Delivering an extremely low no load power consumption (less than 0.3W), it allows the end system to easily meet the worldwide energy requirement. LRS-75 has the complete protection functions and 5G anti- vibration capability; it is complied with the international safety regulations such as TUV BS EN/EN62368-1,BS EN/EN60335-1,BS EN/EN61558-1/-2-16, UL62368-1 and GB 4943.1. LRS-75 series serves as
a high price- to- performance power supply solution for various industrial applications.MODEL
LRS-75-5
LRS-75-12
LRS-75-15
LRS-75-24
LRS-75-36
LRS-75-48
OUTPUT
DC VOLTAGE
5V
12V
15V
24V
36V
48V
RATED CURRENT
14A
6A
5A
3.2A
2.1A
1.6A
CURRENT RANGE
0 ~ 14A
0 ~ 6A
0 ~ 5A
0 ~ 3.2A
0 ~ 2.1A
0 ~ 1.6A
RATED POWER
70W
72W
75W
76.8W
75.6W
76.8W
RIPPLE & NOISE (max.) Note.2
100mVp-p
120mVp-p
120mVp-p
150mVp-p
200mVp-p
200mVp-p
VOLTAGE ADJ. RANGE
4.5 ~ 5.5V
10.2 ~ 13.8V
13.5 ~ 18V
21.6 ~ 28.8V
32.4 ~ 39.6V
43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3
±2.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
LINE REGULATION Note.4
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
LOAD REGULATION Note.5
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
SETUP, RISE TIME
500ms, 30ms/230VAC 500ms,30ms/115VAC at full load
HOLD UP TIME (Typ.)
60ms/230VAC 12ms/115VAC at full load
INPUT
VOLTAGE RANGE
85 ~ 264VAC 120 ~ 373VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
86.5%
89%
89%
90%
91.5%
91.5%
AC CURRENT (Typ.)
1.4A/115VAC 0.85A/230VAC
INRUSH CURRENT (Typ.)
COLD START 65A/230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
PROTECTION
OVER LOAD
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
5.75 ~ 6.75V
13.8 ~ 16.2V
18.75 ~ 21.75V
28.8 ~ 33.6V
41.4 ~ 48.6V
55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT
WORKING TEMP.
-30 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY
Ⅲ; Compliance to BS EN/EN61558, BS EN/EN50178,BS EN/EN60664-1, BS EN/EN62477-1;
altitude up to 2000 meters
SAFETY & EMC
(Note 8)
SAFETY STANDARDS
UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,GB 4943.1,
BSMI CNS15598-1, EAC TP TC 004,AS/NZS 62368.1(by CB),KC62368-1,
BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 9) approved
WITHSTAND VOLTAGE
I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2,-3, GB17625.1,GB/T 9254.1, BSMI CNS15936, EAC TP TC 020,KC KSC 9832, KSC 9835
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2), BS EN/EN55035,
heavy industry level,EAC TP TC 020,KC KSC 9832, KSC 9835
OTHERS
MTBF
3334.3K hrs min. Telcordia SR-332 (Bellcore) ; 667.2Khrs min. MIL-HDBK-217F (25℃)
DIMENSION
99*97*30mm (L*W*H)
PACKING
0.23Kg ; 45pcs/ 11.5Kg/ 0.77CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
7. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft).
8. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
9. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
related products
Product Inquiry
Please leave your message, we will contact you quickly after receiving it, thank you for your support!
common problem
Q
What are the characteristics of cigarette box three-dimensional packaging machine?
A
1. There is no need to adjust the height of the countertops on both sides of the machine when changing the mold, and there is no need to disassemble and assemble the discharge chain or put the hopper, which shortens the four-hour mold replacement time of the traditional machine to only 30 minutes.
2. Adopting a new dual insurance mechanism, the machine does not need to be shut down when it is not running synchronously, nor will it damage other parts.
3. The original one-way hand crank device prevents the machine from shaking in reverse, and the handwheel does not rotate during operation, making the operator safer.
4. The new double rotary film cutting knife can ensure that the machine can be used continuously for many years without a sharpening port, overcoming the defect that the traditional fixed single rotary film cutting blade is easy to wear.
Q
Automatic poker transparent film three-dimensional packaging machine packaging products?
A
Automatic poker transparent film three-dimensional packaging machine is mainly suitable for bulk poker, compressed biscuits, sachima, stickers, sticky notes, wafer biscuits and other bulk or multi-object collection of three-dimensional packaging.
English
繁体中文
简体中文
Deutsch